A basic weather louvre is usually mounted in the vertical and has a row of horizontal blades shaped and positioned so as to minimise the ingress of water. Ideal for use on the
external walls of a building at air intakes or discharges. The free area of a conventional louvre is about 50%. However, the blade pitch can be opened up to give up to 65% free
area but the weather keeping properties decrease
considerably and this would only be recommended where the louvre is protected from driving rain by an adjacent structure.

Louvres can be square or rectangular, triangular, circular, in fact, almost any shape. They can have doors in them, be made demountable for service access or built up into
penthouse units on screens.

There are several less conventional louvres which are designed to:
a) be mounted in a roof pitch (angled louvre).
50mm & 70mm pitch
b) to minimise sand intake (sand trap louvre).
c) to be used in more exposed locations
(double bank chevron louvre).
d) reduce contamination between intake and discharge where one louvre is required to handle both supply and extract air (split louvre). 50mm & 70mm pitch

 
Standard

38mm pitch.
Code 0114. Square or rectangular, flanged louvre with bird mesh for surface mounting in the vertical.
Code 0115. Square or rectangular louvre without flange and with bird mesh for recessed mounting in the vertical.
Code 0214. Square or rectangular louvre with bird mesh and with a reversed flange for surface mounting in the
vertical.
Code 0216. Similar to a Code 0114 but with a
50mm wide flange.

50mm pitch.
Code 0280. Square or rectangular, flanged louvre with bird mesh for surface mounting in the vertical.
Code 0281. Square or rectangular louvre, without flange with bird mesh for recessed mounting in the vertical.
Code 0286. Circular flanged louvre with bird mesh for
surface mounting in the vertical.
Code 0287. Circular louvre without flange with bird mesh for recessed mounting in the vertical.
Code 0292. Triangular flanged louvre with bird mesh for surface mounting in the vertical.
Code 0293. Triangular louvre without flange with bird mesh for recessed mounting in the vertical.
Code 0298. Square or rectangular penthouse louvre with bird mesh for curb mounting.

Code 0211. Square or rectangular flanged split louvre for surface mounting with top section for upward and lower section for downward discharge.
Code 0208. Square or rectangular split louvre without flange for recessed mounting with top section for upward and lower section for downward discharge.

75mm Pitch.
Code 0282. Square or rectangular, flanged louvre with bird mesh for surface mounting in the vertical.
Code 0283. Square or rectangular louvre, without flange with bird mesh for recessed mounting in the vertical.
Code 0288. Circular flanged louvre with bird mesh for surface mounting in the vertical.
Code 0289. Circular louvre without flange with bird mesh for recessed mounting in the vertical.
Code 0294. Triangular flanged louvre with bird mesh for surface mounting in the vertical.
Code 0295. Triangular louvre without flange with bird mesh for recessed mounting in the vertical.
Code 0609. Square or rectangular penthouse louvre with bird mesh for curb mounting.
Code 0209. Square or rectangular flanged split louvre for surface mounting with top section for upward and lower section for downward discharge.
Code 0213. Square or rectangular split louvre without flange for recessed mounting with top section for upward and lower section for downward discharge.


100mm pitch.
Code 0284. Square or rectangular, flanged louvre with bird mesh for surface mounting in the vertical.
Code 0285. Square or rectangular louvre, without flange with bird mesh for recessed mounting in the vertical.
Code 0290. Circular flanged louvre with bird mesh for surface mounting in the vertical.
Code 0291. Circular louvre without flange with bird mesh for recessed mounting in the vertical.
Code 0296. Triangular flanged louvre with bird mesh for surface mounting in the vertical.
Code 0297. Triangular louvre without flange with bird mesh for recessed mounting in the vertical.
Code 0610. Square or rectangular penthouse louvre with bird mesh for curb mounting.

Sandtrap.
Code 0680. Square or rectangular sandtrap louvre flanged for surface mounting.
Code 0681. Square or rectangular sandtrap louvre without flange for recessed mounting.

Angled
Code 0682. Square or rectangular flanged louvre with bird mesh for surface mounting in a angled roof up to 40 degrees from the vertical.
Code 0683. Square or rectangular louvre without flange with bird mesh for recessed mounting in an angled roof up to 40 degrees from the vertical.

 

 
Standard Specification

SIZES
38mm pitch.
Any nominal length or height up to 1500mm provided the other dimension does not exceed 1200mm.

50mm pitch.
Any nominal length or height in one piece, provided the face area does not exceed 4 sq metres. However, any nominal length or height can be made up from sections bolted together and, where necessary,
supported on a metal framework. The maximum
diameter for a circular louvre is 2000mm in one
section. A larger diameter can be manufactured in
multiple sections and bolted together.

75mm pitch.
Any nominal length or height in one piece, provided the face area does not exceed 4 sq metres. However, any nominal length or height can be made up from sections bolted together and, where necessary,
supported on a metal framework. The maximum
diameter for a circular louvre is 2000mm in one
section. A larger diameter can be manufactured in
multiple sections and bolted together.

100mm pitch.
Any nominal length or height in one piece provided the face area does not exceed 4 sq metres. However, any nominal length or height can be made up from sections bolted together and, where necessary,
supported on a metal framework. The maximum
diameter for a circular louvre is 2000mm in one
section. A larger diameter can be manufactured in
multiple sections and bolted together.

SANDTRAP
Any nominal length or height in one piece provided the face area does not exceed 4 sq metres. Larger sizes can be made up but they become very heavy to handle. Please contact the factory for details.

ANGLED
Any nominal length or height in one piece provided the face area does not exceed 4 sq metres. Larger sizes can be made up but they become very heavy to handle. Please contact Head Office for details.

CONSTRUCTION
Manufactured from aluminium extrusions with mitred corners The 38mm pitch louvres have cleated corners. All others have welded corners.
The bird mesh is manufactured from steel wire with welded joints and 25mm cells.

Finishes
Louvres are mill finish aluminium. The bird mesh is galvanised after manufacture.

FIXINGS
Surface mounted louvres are fixed through the face flange. Screw holes are not provided as the centres required vary considerably. Fixing type 0F2. Recessed louvres are fixed through the stack. Screw holes are not provided. Fixing Type 0F2.

PACKAGING
Louvres are packed in polythene and then
sandwiched between two pieces of hard board and banded with protective cardboard corners and sides.

TECHNICAL INFORMATION
See pages 8 - 10

 

Optional/Additional Alternatives

Finishes
Any BS, RAL or NCS colour. 38 mm pitch, Code 0145. Other pitches, Code 0146. please specify the colour reference.
Satin anodised. Code 0147 satin. It may be possible to anodise to other colours and finishes depending on quantity. Please contact the Head Office for details.

FIXINGS
The flanges can be pre-drilled. Please provide details of fixing centres and whether or not countersinking is required. Fixing type OF1. Fixing tabs can be provided to the rear of the stack to fix to brick or steel work. Please provide details of your requirements. Fixing type OF 11.

DRIP SILLS
A drip sill can be provided, in the same finish as the louvre. Details of the codes and dimensions are given below.

SUPPORTING FRAMEWORK
The necessary supporting framework in steel or
aluminium can be supplied to support multiple
sections, where necessary, or to provide a louvred screen. Please provide details.

DOORS
Single or double doors can be provided in all louvres and penthouses except for the 38mm pitch range.
The doors are hinged and fitted with Eurolocks.
Code 0279. Please provide details.

DE-MOUNTABLE PANELS, HINGED OR
CUTAWAY SECTIONS
These can be provided to your requirements. Please provide details. The louvre product Code prefix becomes 9 instead of 0.

 

 
Ordering Details

• The code for the basic grille should have 13 digits.
See page 1.
• Please always give length first, then height.
• Add codes for additions/alternatives as suffixes.

EXAMPLE:
Example. A 50mm pitch flanged triangular louvre with a nominal base dimension of 1500mm and a nominal base to apex height of 1000mm with a hinged access door in it for surface mounting with pre-drilled fixing holes would be coded:- 0292/01500/1000+0279+0F1.

Applications. Supply * Extract * Sidewall *

 

38mm PITCH (STANDARD)
38mm PITCH (50mm FLANGE)
50mm PITCH 75mm PITCH
EXTERNAL WEATHER LOUVRES
PERFORMANCE DATA 38mm PITCH
• We would recommend that, on air intake, the duct velocity does not exceed 1.5m/s (3.0m/s core velocity) at the louvre in order to minimise the ingress of water. This can be increased to 2.0m/s (4.0m/s core velocity) on extract applications provided the noise and pressure drop criteria are met. Example. to select a louvre for air intake handling 0.3m3/s, place a rule on this point on the volume line and ensure that it crosses the duct velocity line @ 1.5m/s. Note where the rule the pivot line and then rotate the rule about this point to obtain a suitable combination of length and height. In this case a 450mm x 450mm. Read off the pressure drop and N.R., adding 10% to the pressure drop if birdmesh is fitted.
EXTERNAL WEATHER LOUVRES
PERFORMANCE DATA 50mm PITCH

• We would recommend that, on air intake, the duct velocity does not exceed 1.5m/s (3.0m/s core velocity) at the louvre in order to minimise the ingress of water. This can be increased to 2.0m/s (4.0m/s core velocity) on extract applications provided the noise and pressure drop criteria are met. Example. To select a louvre for air intake handling 0.3m3/s, place a rule on this point on the volume line and ensure that it crosses the duct velocity line at 1.5m/s. Note where the rule crosses the pivot line and then rotate the rule about this point to obtain a suitable combination of length and height.

In this case a 450mm x 450mm. Read off the pressure drop and N.R., adding 10% to the pressure drop if birdmesh is fitted. To calculate the size of a louvre to handle more than 2.0m3/s divide the volume by a number that gives a volume equal to less than 2m/s and use the Nomogram. It is reasonably safe to read the pressure drop and NR from the nomogram and use it for the larger louvre. Remember to multiply the resulting duct area shown on the pivot line by the same number used to divide the volume. This will give the face area of the required louvre.

EXTERNAL WEATHER LOUVRES
PERFORMANCE DATA 75mm PITCH

• We would recommend that, on air intake, the duct velocity does not exceed 1.5m/s (3.0m/s core velocity) at the louver in order to minimise the ingress of water. This can be increased to 2.0m/s (4.0m/s core velocity) on extract applications provided the noise and pressure drop criteria are met. Example. To select a louvre for air intake handling 0.3m3/s, place a rule on this point on the volume line and ensure that it crosses the duct velocity line at 1.5m/s. Note where the rule crosses the pivot line and then rotate the rule about this point to obtain a suitable combination of length and height.

In this case a 450mm x 450mm. Read off the pressure drop and N.R., adding 10% to the pressure drop if birdmesh is fitted. To calculate the size of a louvre to handle more than 2.0m3/s divide the volume by a number that gives a volume equal to less than 2m/s and use the Nomogram. It is reasonably safe to read the pressure drop and NR from the nomogram and use it for the larger louvre. Remember to multiply the resulting duct area shown on the pivot line by the same number used to divide the volume. This will give the face area of the required louvre.

 
 
 
 
 
 

 

 

 

 
   
 
 
 
   
   
   
   
   
 